V 1.9.9.9
- New "Samples No" function added to sweep window. You
can now change the number of samples per sweep. This
feature is only available for V4 units!
Default is "auto" (same number of samples as in the
past version of LCS). Minimum sample points is 51. A
higher number of sample points offers a better sweep
resolution but also slows down the sweep.
V 1.9.9.8
- Number of frequency points for sweeprecording now
unlimited (was 2000 points). Very usefull for recording
EMC sweeps. If you want to reimport files with more then
20000 frequency points you have to give your Ok in a pop
up window.
- Image Supression function now also works with the
EMC-Filter of the V4 series (5MHz, 120kHz, 9kHz and
200Hz).
V 1.9.9.7
- The EMC-Filter of the SPECTRAN V4-series (5MHz,
120kHz, 9kHz and 200Hz) are supported.
- The Sweep-Display of the V4 SPECTRAN units can be
switched off in the Sweep-window by "Display off". This
offers, at fast sweeps, an significant increase of speed
which can be seen easily at the Sample-Speed-View at the
right side of the Software.
- Now the RMS and Min/Max Detectors of the V4 can be
set in the sweeparea window.
- The INTERNAL attenuator of the V4 SPECTRANs can be
adjusted in the sweeparea window at "Attenuator".
Laymen should leave this function at "auto"!
- "Auto-Delay OFF" in the sweeparea window can turn of
the automatic delay of the auto-attenuator from the V4
SPECTRANs.
This adjustment must be manualy send to the SPECTRAN
(this feature is not supported by the "send
sweepparameter immediately to the unit" function). More
information can be found at the V4 firmware history.
- Meaningless Puls-Modus option removed from the V4
units.
- In the time-course-display it´s now possible
(by pressing the left mouse button) to scroll in the time
axis.
V 1.9.9.6
- Error removed at the Unit window in the Results
menue.
V 1.9.9.5
- FINALLY it is integrated: The daily view feature
for the HF-series.
This function can be activated/deactivated at "View" with
"Daily view" or by pressing "T".
The daily view shows the data of the result window as a
graphical trend in the timeline.
If you move the mouse over the trend of the daily view,
referring to this the level in dBm, the frequency and the
time will be showed directly.
At the left side you can choose between a a 24h, 6h or 1h
view. With the reset function you can reset/delete the
results.
The screen will be rescaled automatically if the maximum
level changes.
As a special feature the AVG-function will also be
considered. With this feature it´s possible to
filter out short level variations or to show only results
of a specific timeframe.
- Cal-Data added for new, radial isotropic
Broadbandantenna OmniLOG 90200.
V 1.9.9.4 (Our CeBIT Version)
- Software Image Suppression (SIS) Mode integrated.
Allows better suppression of interfering signals (Extras
-> Options), switched on by default, only for signals
below -65dBm.
- Zoom mode improved:
- When zoomed in, values will be rounded.
- The last Zoom step will be cached. - Right click after
a zoom in the middle area, will change to the last zoom
step.
- Correct display of installed Hardware-Options
- Trace History function is automatically activated
after a sweep-file load. The Trace History function will
be automatically deactivated by pressing the Play-Button.
V 1.9.9.3
- Exposure limits expanded. Now it is possible to
choose the following limits for the HF-60100 V4 Spectrum
Analyzer:
EN50371 Class A (30MHz-1GHz)
EN50371 Class B (30MHz-1GHz)
EN55011 Class A (30MHz-1GHz)
EN55011 Class B (30MHz-1GHz)
EN55022 Class A (30MHz-1GHz)
EN55022 Class B (30MHz-1GHz)
In addition the "limit-lines" will be showed as a red
line in the Spectrogram window.
Please note that it is only possible to measure this
limits with a suitable Antenna (BicoLOG-series) or with
our Probe-Set (PBS2). It is also necessary to use the
recommended preamplifier for the HF-60100 V4 (Option 020
and 022).
The external Preamplifier (Option 022) can be chosen at
"Attenuator" in the "Calibration" window (Opt 022 PreAmp
DC-1GHz).
- Exposure limits are expanded below the Spectrogram
window (View -> Show Limits). By clicking the right
mouse button at the exposure limits diagram, you will see
a new ICNIRP display and a comparison between "ICNIRP
public" and "ICNIRP occupational".
V 1.9.9.2
- Units expanded for extremely small field strengths.
Now the smallest unit is "Zepto".
V 1.9.9.1
- Wrong cable or antenna settings for the frequency
range will now generate an error.
- AVG-Quantity set to 20 by default.
V 1.9.9.0
- Frequency range of HF-60100 V4 expanded to
9.4GHz.
- The HF-Modulee noise level will be automatically
adjusted to each connected unit, i.e. all V4 units
automatically set to -170dBm.
- "Switch Background" mode integrated in the View menu.
This function allows the user to switch the background
colour between white and black (Hotkey: I)
- Cable settings from the Spectran will not be
considered any more, a "double calibration" is not
possible any more.
- If the chosen frequency range does not accord to the
chosen/connected antenna, a warning error will
appear.
- NF-Modulee: The marker-minimum is set to 0 by
Default.
- NF-Modulee: Sweepstart now possible without choosing
a Profile.
- Different settings from the HF-Modulee corrected in
the NF-Modulee. The sweep in the NF-Modulee should now
work perfect.
V 1.3.0.5
- Our external PBS2 40dB PreAmplifier of the Aaronia
Probe-Set and EMC-bundle 1 is added to "attenuator" at
the "calibration" window.
- EN55022 and 55011 settings (only for Spectran
HF-60100 V4) added to "Profile" in the "Sweep"
window.
- Our LowLoss 5m and 10m SMA cables are added to
"calibration" in the "cable" window.
- Menu "Options" at "Extras" switched on for the
NF-Modulees.
V 1.3.0.4
- Reference, Dynamic and Noise will be adjusted
automatically to -150dBm if you use the SPECTRAN V4.
- Unit "Atto" added. This is necessary for very small
field-strength measurement results with the SPECTRAN V4.
Maybe "Zepto" and "Yocto" will follow...
- Switchable "Detector Mode" (Peak, AVG etc.) added for
the SPECTRAN V4.
- Error removed in the dBµV/m display.
- Now the "Sum Marker" function also works in the AVG
and HOLD mode.
- Calibration error of the NF-Modulee by considering
the cable.ini removed.
- Conversion-interruption of the Filemanager (i.e. on
pressing the CLR-button of the SPECTRAN NF) removed.
- The DFT-mode sampletime in the NF-Modulee will be
limited automatically to 5s. Wrong insertions are not
possible anymore.
- AVG-quantity was set wrong at the first start of the
LCS Software. Now it is automatically 0.
- Offset-Display enabled again.
- The headlines "Freq (MHz) Value (dBm)" were
interchanged in the HF logger data display. Error
removed.
- Adding of "CRLF" to saved logger datas in the
filemanager removed.
- If you had choosen "pico" or "femto" in the
Spectrogram window of the NF-Modulee as scale unit, the
markers were shown with too many digits. Error removed.
V 1.3.0.3
- NF-Modulee expanded by Lg10000 in the Spectrogram
window at "scale/scale"
- NF-Modulee expanded by the following scale factors in
Spectrogram window at "scale/scale": 10Lg10, 100Lg10,
1000Lg10, 10Lg100, 100Lg100, 1000Lg100, 10Lg1000,
100Lg1000, 1000Lg1000, 10Lg10000, 100Lg10000 and
1000Lg10000.
Measurement results with high dynamic will now be
displayed better.
V 1.3.0.2
- Fixed wrong AVG-Display after changing the span or
using the zooming function.
V 1.3.0.1
- Disk-Symbol was changed to the Record-Symbol (red
dot). You can now stop the record by klicking on the
record symbol too.
- HF-Modulee now aktivates no autoscaling at
startup.
- If "Allways send parameter immediately to unit" is
aktivated all changes in the Calibration-Window will be
used too.
V 1.2.9.11
- Sampletime expanded in HF-Modulee (1mS, 2mS, 5mS,
10mS, 20mS). Those can only be used with the new
SPECTRAN V4 units.
- Spectrogram-Window offers the new feature "Autom.".
This enables an autorange-function of the spectrum
window.
- Spectrogram-Window offers a new feature "adjust".
This automatically scales the spectrum window with a
click.
- With "Smooth Spectrogram" in "Extras", "Options" you
can activate/deactivate the spectrogram display
smoother.
- NF-Modulee now offers "Noise" per default as Zero
(better display).
- New Unit "dbµV/m" added to HF-Modulee.
- Added new feature to the navigation bar: With the
disk symbol you can start a recording (record
function).
- If "Always send parameter immediately to unit" is
activated all changes in the Sweep-Window will be used
too.
- A new "Compress" option has been added to the
Spectrogram-Display for HF SPECTRAN models. This feature
can be used to "squeeze" the spectrogram display by a
factor of up to 40 in order to get a faster overview of
large data sets.
V 1.2.9.9
-
New filter (RBW & VBW) added (3kHz, 10kHz,
30kHz). Those only work with the new SPECTRAN V4
units. All other SPECTRAN units are limited (by
hardware) to 100kHz.
V 1.2.9.8
- Sweeparea expanded to 9GHz. This only works
with the new SPECTRAN V4 units with 9GHz expansion.
- New feature "PreAmplifier" added to "Sweeparea"
window. This feature offers about 15dB higher sensitivity
to the new SPECTRAN V4 units with ultra low noise
Pre-Amplifier (Option 020).
- The lines of manually set marker now also show up in
the spectrogram window.
- LCS now automatically switches between NF and HF
layout depending on the reloaded data file (auto-detect
feature).
V 1.2.9.7
- New feature "Trace History" added to the "Sweeparea"
window. Press and hold the left mouse button to mark an
area in the spectrogram window. All readings like AVG,
MAX and marker will now ONLY be based on this data. This
is a truly clever feature. This feature also works on
reloaded files.
V 1.2.9.6
- Automatic recognition of the connected SPECTRAN model
(HF/NF). Consequently, a SINGLE version of the LCS
software now works for ALL models.
- Manual markers now also work in the HF Modulee.
- Automatic frequency display between manual markers.
This is a truly clever feature.
- Added new unit "dBµV/m" in the NF Modulee
(E-field sensor).
- Corrected erroneous spectrum display in A/m and Gauss
modes in NF Modulee.
- Corrected erroneous marker frequency display in the
HF Modulee.
- Corrected error with LOG display in the NF
Modulee.
- The "waterfall" display is now labelled
"Spectrogram".
V 1.2.9.5
- The sweep range window has been enhanced with various
features:
- The "Detector" option now offers the following
choices:
RMS or
Min/Max
- The "Trace" option can now show the measurement data as
various different functions in the sweep window. All
functions can be displayed SIMULTANEOUSLY. Each function
uses its own distinct colour:
Sweep (regular sweep feature) [green]
Shadow (shadow copy of the previous sweep)
[blue]
Avg (average function with an arbitrary FIFO
buffer depth and CLR option) [yellow]
Max hold (hold feature with CLR option)
[red]
- Data from the "waterfall" display can be stored and
retrieved at any time (HF and NF). This is accomplished
through the "File" menu using the "Save data" or "Save
data as" options, respectively.
It is also possible to add descriptive notes to each
saved file.
These notes can be retrieved after reading using the
"File" menu's "Properties" option. The following fields
are available:
- Title (also displayed in the main window title)
- Site of measurement
- Measurement date
- Name
- Organisation
- Department
- Comments
- An arbitrary number of markers can now be set
MANUALLY. An ideal feature for assessment of channel
offsets, for instance. To use this feature, a new option
"Manual" has been added to the "Waterfall" window. When
activated, a blue subwindow will appear right above the
sweep window, where markers can be set as desired.
Markers will be sorted alphabetically and displayed as
usual. To clear all markers, click "CLEAR". By holding
the left mouse button, markers can also be moved
interactively when created. By clicking a marker once
again, it will be erased. When manual markers are
activated, automatic markers will be disabled.
Consequently, the measurement results shown in the
"Results" window now solely correspond to the manually
set markers.
- Corrected an error when using high display
resolutions (more than 2100 pixels). Finally, our nice
30-inchers with 2560x1600 pixels resolution can unleash
their full potential...
- Improved marker display. Two rows are now used in
order to more clearly display the frequency and
level.
- The "Peaks" label has been replaced by the more
correct expression "Marker".
- The frequency of the sweep window is now displayed
centered in a seperate line.
- The current physical unit is now displayed centered
and aligned to the scaling.
- Logger data is now displayed correctly with NF
SPECTRAN models.
- Various new profiles for the NF series have been
added or adjusted (for example, ADSL and ADSL2+ for using
the NF SPECTRAN as a DSL tester).
V 1.2.9.2
- When using the AVG feature, it is now possible to
turn off the sweep by setting the "Hide sweep during
Maxhold" option in the "Extras" -> "Options" menu.
Only the AVG display of the measurement results will
appear.
V 1.2.9.1
- New AVG feature (NF models). In the "View" menu, find
the new "Show average (AVG)" option, which can also be
activated at any time by using the "A" hotkey.
This feature is very useful for visualizing very noisy
signals.
You can also set the number of sweeps used for average
calculation in the "Extras" -> "Options" menu ("Sweeps
for average").
- "Waterfall" data can now optionally be saved in 3D.
V 1.2.9.0 (for NF series)
- Automatic recognition of the connected SPECTRAN model
(HF or NF) and adjustment of feature set.
- New feature "Reset data" in the "File" menu. This
option clears the "Waterfall" display and all data
currently in memory.
- New option "Load data" in the "File" menu. This
option will read a file previously saved using the "Save
data" or "Save data as" options, including the complete
"Waterfall" display.
- Extremely improved graphics display performance
(approx. 1000%).
- Visually improved "Waterfall" display with a new
softening filter.
- Added a new "Search" option in the "Extras" menu of
the file manager. This feature will search all files in
SPECTRAN's memory starting at number 1000 in the
"Personal" directory. This way, "lost" files can be
located and possibly deleted using the "Delete" option to
save some memory.
- New "Adjust scale" option in the "View" menu.
Intended for the NF SPECTRAN models, this feature will
quickly perform an automatic adjustment of display
scaling and can also be called up at any time using the
"S" hotkey. A very handy feature given the enormous
dynamic range of SPECTRAN.
- New "Automatically adjust scale to maximum" in the
"Extras" menu under "Options". This feature avoids
display "overflow" when dealing with very high levels and
will automatically scale the display maximum if
necessary.
- New feature "Device properties" in the "?" menu.
Various information about the connected SPECTRAN device
will be displayed here (if available):
- Model (for example, "HF-6080")
- Revision (for example, "3" for the SPECTRAN Rev3)
- Board revision
- Battery (factory-installed battery type)
- Firmware (version installed at the factory. ATTENTION:
This property is currently set at the factory and NOT
updated when you install a new firmware version!)
- Serial number
- Last calibration (for NF models, the internal 3D
magnetic field sensor)
- Last calibration of internal 1D E-field sensor (only NF
models)
- Last calibration of internal 3D static magnetic field
sensor (only NF models with Option 006)
- Installed options (list)
- A new "Compress" option has been added to the
"Waterfall" display for NF SPECTRAN models. This feature
can be used to "squeeze" the waterfall display by a
factor of up to 40 in order to get a faster overview of
large data sets.
V 1.2.6.1
- Markers are now displayed in the selected unit.
Previously, they were always shown in dBm.
- New W/cm² unit added to the results window.
- New "f" prefix (femto) added to the results window.
This has become necessary especially for the new
W/cm² unit.
-
A quadratic mean of measurement results can now be
calculated using the new "Sum peaks" option. The
values of the currently set markers will be used. This
feature allows standards-conforming evaluation
according to ICNIRP or the German BImSchV 26.
However, you should make sure that the number of
markers corresponds to the actual number of signal
sources in question, as otherwise, the resulting
readout can be too large, as a single signal might
correspond to several markers.
Of course, this feature does not make sense when using
the dBm and dBµV settings. Consequently, the
software prevents this combination of options from
being used.
V 1.2.5.7 PLUS
- Added UMTS, GSM900 and GSM1800 frequency list for the
UK.
V 1.2.5.5
- Error in assembler removed.
V 1.2.5.3
- In the sweep range window, the new "PEP" feature has
been added. Using this feature, the so-called "Peak
Envelope Power" (abbr.: PEP) can now be measured. PEP
displays the RF peak power output of a Moduleated
signal. In this regard, all profile parameters have
been given an overhaul as well. They also have been
extended by many new presets; among others, channel
assignments for Switzerland (GSM) and Austria (UMTS). In
some profiles, PEP measurement has been deactivated. In
these cases, PEP measurement does not make sense, as the
difference is neglectible. In some cases, it might also
not yet have been implemented. We would like to
reemphasize that all presets and values in profiles are
given without any warranty.
- When the "Send sweep parameters immediately" function
is turned on, the settings of the currently selected
profile will now always be sent to SPECTRAN at once and
the sweep started. This notably facilitates changing
between different profiles rapidly.
V 1.2.5.2
- The long awaited "luxury" MaxHOLD feature for the
sweep display has now been added. Works as follows: The
menu entry "Hold maximum" in the "VIEW" menu activates
this feature. Yet more easily, you can just press the "M"
hotkey, which will activate or deactivate/reset the
MaxHOLD feature at any time. As soon as the MaxHOLD
feature is active, display of the sweep graphic is shown
in RED. This graphic will only change in case HIGHER
values than before are being measured. Otherwise, the
display stays "frozen". Also, the markers now only
correspond to the MaxHOLD display. Additionally, it is
now possible to DEACTIVATE the "Hide sweep during
Maxhold" option in the "EXTRAS" menu under "Options".
Like this, the current sweep can ADDITIONALLY be
displayed in GREEN.
- The maximum length of channel names has been heavily
extended, thus allowing more information to be displayed.
The sweep "profiles" are being reworked to reflect this
and will be available for download within a few days with
new, optimised parameters.
- New function "Offset" in the sweep profile scripting
language. Syntax: Offset = dB, where dB can be given with
two decimal places.
- The ZERO crossing is not being considered a peak
anymore.
- When nothing ("zero") is being measured, "---" is now
being displayed instead of "-120".
- Window position is not being saved anymore if the
window has been minimized before.
- If the sweep range had been started with "Zero", no
display of results in the "Results" window has taken
place. This error has been corrected.
- An error in the assembler (file manager) has been
corrected.
V 1.2.4.0
- Error in window positioning has been fixed. In a few
cases, the software could not be initialized correctly at
start because "negative" window positions were
determined.
V 1.2.3.0
- ATTENTION! To correctly place the new tools windows
on the first run after installation, you need to launch
the software with the Ctrl-key held down! Reading the
stored data of the internal SPECTRAN data logger is now
significantly easier: simply store the logger data under
program number "1000". Having done so, you can just read
the data directly as CLEAR TEXT in the LCS software under
"Extras" in the "File manager" and, for instance, paste
them into a spreadsheet: for this purpose, the file
"logger data" is available in the "Spezial" directory.
Simply select the file "logger data", and the logger data
is immediately being displayed as a continuous list/table
(first level in dBm, then frequency in MHz). Here, the
dBm values are being displayed with two decimal places.
ATTENTION: With bigger amounts of data, reading out all
data can take a few moments...
V 1.2.2.1
- ATTENTION! To correctly place the new tools
windows after installing for the first time, you need to
launch the software while holding down the
"Ctrl"-key!
- Depending on exposure limit or power calculation,
there are different accumulation modes. In the "Exposure
limits" tool window, the standard modes are now
selectable via mouse click:
- In the file "Grenzwerte.ini", you can program new
accumulation functions directly into the respective
profiles:
Every exposure limit can now have a setting "PeakSum".
Here, the following parameters are available:
0 = Exposure limit display only uses the highest peak
for calculation
1 = Exposure limit display calculates the square root
of the sum of the squares of all peaks (only for peaks
based on field strength)
2 = Exposure limit display calculates the sum of all
peaks (only for power flux density based peaks)
If nothing is selected, 1 or 2 is automatically chosen
- so if you only want peaks, you need to choose 0
explicitly.
V 1.2.1.1
- Finally, exposure limit display works correctly again
even after a restart ;-)
V 1.2.1.0
- Corrected display error in Power flux density / Field
strength display. Sometimes too many decimal places were
shown, or the spectrum display was missing.
- The last configuration for standard exposure limits
is now restored on restart.
- The "Sweep shadow" can now be turned off in Extras
-> Options.
- The results display now resets completely if no new
readings are coming in. Before, the last value remained
in the display.
V 1.2.0.1
- In the "exposure limits" toolbar, two new
functions have been added (and the old function "Max
Display" hasbeen removed):
- "Linear" = Here you can change the scaling
of the exposure limit display. Very helpful with
"overflowing" or "hardly changing" exposure limit
readings.
- "Logarithmic" = Here you can change the
"dynamics" of the exposure limit display. Especially
helpful for getting "sudden peaks" or "very low rates
of change" under control.
- Furthermore, there is a new info field called
"Exposure limit". It displays the selected exposure
limit and the used unit.
- Changes in the "Exposure limits" toolbar are now
respected IMMEDIATELY.
V 1.1.0.8
- New toolbar "Exposure Limits". Here, the
following features are available:
- "Default exposure limits" = Here, a vast variety
of exposure limits can be chosen. After selection,
the current reading will be displayed as a green bar
with percentage display. On exceeding the limit, the
bar will turn red. In addition to the selected
exposure limit, 4 further bargraphs can be
displayed:
- "Average" = Displays the current average
(over the exposure time).
- "Average maximum" = Displays the highest
average maximum (over the exposure time) that has
ever occured.
- "Local maximum" = Displays the current
maximum over the exposure time.
- "Absolute maximum" = Displays the highest
reading that ever occured.
- "Exposure limit" = Informational field.
Displays the selected exposure limit and its
unit.
- "Exposure time" = Here you can adjust the
timespan used for the functions "Average", "Average
maximum" and "Local maximum" via slider or direct
input.
- "Linear" = Here you can change the scaling
of the exposure limit display. Very helpful with
"overflowing" or "hardly changing" exposure limit
readings.
- "Logarithmic" = Here you can change the
"dynamics" of the exposure limit display. Especially
helpful for getting "sudden peaks" or "very low rates
of change" under control.
- "Reset display" = Resets all bargraphs.
All exposure limit calculations are
restarted.
ADVANCED HINT: Press the right mouse button
in the exposure limit window for loading CUSTOM
exposure limits. These can be added to the file
"limits.ini". Various examples of the complex
functionality are already included, amongst others, a
comparison (simultaneous display) of the old "Salzburg
precautionary limit" and the ICNIRP limit. For the
scripting master, everything is possible here
;-)
- New Toolbar "Calibration" added. Here, the
following functionality is available:
- "Antenna" = Here
you can select EXTREMELY PRECISE calibration
data of various antennas (exact to 10MHz!). The
corresponding entries for our HyperLOG antennas are
included.
By selecting "None (0dBi)", no antenna is being
chosen.
- "Cable" = Here, EXTREMELY PRECISE
calibration data of a wide variety of cables can
be selected. The matching entry for our included 1m
RG316U cables is available as a preset.
By selecting "None (0dB)", no cable is being
chosen.
- "Attenuator" = Here you can select
EXTREMELY PRECISE calibration data of a wide
variety of attenuators. ATTENTION: This function is
ONLY applicable to the HF-6080! The matching entry
for our 20dB attenuator is already included.
By selecting "None (0dB)", no attenuator is being
chosen.
- "Calibration" (OFFEST) = Here you can
perform a MANUAL PRECISION CALIBRATION using a slider
or direct numeric entry. A really nice function, as
this way precision is adjustable in 0,1dB steps!
Hence, you can, for example, "normalize" the readings
of SPECTRAN as close as 0,1dB to the readings of
foreign units. Another use of this function would be
to do a HIGHLY EXACT calibration of your SPECTRAN
including the used cables, in the desired frequency
range, using an external signal generator! As a
precaution, the current setting is continuously being
displayed in the spectrum window.
- In the results window, cable/antenna correction
factors are now also being displayed below the frequency
indication. A great feature for all professionals.
- For quick checks, the selected antenna and cable will
be shown with "?" in the titlebar.
- In the "Sweep range" window, the sweep time unit [ms]
is now displayed as well.
- The nonsensical "Copy and Paste" symbol in the
titlebar has been removed.
- Fixed errors in dBm display: Until now, the antenna
gain has been added to the displayed dBm figure.
- Fixed an error with transposing the frequency range:
If the range was moved too far to the right, frequency
display has erroneously been turned off.
- Calibration of antennas and cables are now easier to
use: When selecting antenna- or cable calibration data in
the LCS, the already applied calibration data from
SPECTRAN used to be added as well, unless the user didn't
reset them prior to calibration (Type "None"). Now,
calibration data selected in LCS have priority. Data
selected in the SPECTRAN will be overridden.
V 1.0.8
- Sweep abort feature added (be sure to update
the firmware as well!). This simplifies usage immensely,
as you don't need to wait for the end of a sweep anymore
for transferring new data.
- As soon as the upload button is activated, the old
sweep is aborted and a new sweep with the new data is
started.
- In the "Extras" menu, under "Options", there is a new
option "Update sweep now". When this function is
activated, you do not need to push the upload button
anymore. Instead, whenever you change a sweep parameter
and press Enter, a new sweep is started automatically.
VERY PRACTICAL!
-
ZOOM functionality added.
- ZOOM IN:
By "dragging" a range in the spectrum window using
the left mouse button, a new frequency range
can be selected (will appear in red). Release the
mouse button, and the zoom takes place.
- ZOOM OUT:
By clicking the right mouse button in the
spectrum window, the SPAN will be doubled in width
and the start- and end frequencies will be adapted
proportionally. Thus, you get a NEGATIVE zoom.
|